CROUZET CONTROL
For control of over-current in ac networks via internal current transformer. The unit requires supply voltage. The current conductor is run through the hole in the relay (current transformer) for measurement of the ac current. The current transformer hole is 10 mm. The MIC relay controls over-currents. The relay activates (closes) when the current exceeds the limit value that is shown on the front and drops out (opens) when the current drops below the limit value, minus the hysteresis value (static 15 % of the displayed limit value). When Y1 is connected to A1 (+), the relay function is inverted. The relay drops out when the current exceeds the limit value shown on the front and activates when the current drops below the hysteresis value (over-current). The relay can also be used for under-current function. Contact OEM Automatic's Panel Components product area about this function.
Time Delay Start | 0,5 s |
---|---|
Lower Limit | 2A |
Approvals | CE, CSA, GL, RoHS, UL |
Breaking capacity | 5A, 250V AC/DC |
Overload Continuous Max | 100 A |
Temperature range to | 50 °C |
Temperature range bearing, to | 70 °C |
Temperature range from | -20 °C |
Recovery Time Min | 0,2 ms |
---|---|
Temperature range bearing, from | -40 °C |
Weight | 110 g |
Supply voltage | 24-240V AC/DC |
Output | Relay 1 pole C/O |
Current Transformer Diameter | 10 mm |
Upper Limit | 20A |
For control of over-current in ac networks via internal current transformer. The unit requires supply voltage. The current conductor is run through the hole in the relay (current transformer) for measurement of the ac current. The current transformer hole is 10 mm. The MIC relay controls over-currents. The relay activates (closes) when the current exceeds the limit value that is shown on the front and drops out (opens) when the current drops below the limit value, minus the hysteresis value (static 15 % of the displayed limit value). When Y1 is connected to A1 (+), the relay function is inverted. The relay drops out when the current exceeds the limit value shown on the front and activates when the current drops below the hysteresis value (over-current). The relay can also be used for under-current function. Contact OEM Automatic's Panel Components product area about this function.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
Can you distinguish between a bifurcated contact and a normal contact at a glance?
The need for flexible, modular systems shapes machine and system engineering. Decentralization of the system components has proven to be an important factor for success.
The PIANO PIC series is designed for applications that require reliable DIN rail power supplies, which are focused to deliver the most widely required customer functionalities. Our PIC units offer this simplicity without making compromises on PULS’ renowned qualities; efficiency, service lifetime, reliability and size.
The new WADI product family by Jacob features a completely redesigned gland rubber, which allows extensive sealing and tightening area.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Time Delay Start | Lower Limit | Approvals | Breaking capacity | Overload Continuous Max | Temperature range to | Temperature range bearing, to | Temperature range from | Recovery Time Min | Temperature range bearing, from | Weight | Supply voltage | Output | Current Transformer Diameter | Upper Limit | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MIC CURRENT CONTROL RELAY
Art:
84871122
Copied
|
0,5 s
|
2A
|
CE, CSA, GL, RoHS, UL
|
5A, 250V AC/DC
|
100 A
|
50 °C
|
70 °C
|
-20 °C
|
0,2 ms
|
-40 °C
|
110 g
|
24-240V AC/DC
|
Relay 1 pole C/O
|
10 mm
|
20A
|
|