LIYY PVC electronic cable is suitable for use in industrial applications such as scales and control panels to transmit measuring, control and voice signals.
Number Of leads | 2 |
---|---|
Cross-Section | 0.14 mm² |
Material Outer Jacket | PVC |
Shielded | No |
Nominal Voltage | Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V |
Diameter Outer -5% | 3.3 mm |
Temperature Range The Use Of | -40 °C |
Temperature Range For Flexible Use | 80 °C |
Temperature Range Flexible Use Of | -5 °C |
Copper Weight | 2.7 kg/km |
Weight | 12 kg/km |
---|---|
Core Insulation | PVC |
Core identification | Colour Coded |
Approvals | REACH, RoHS |
Test Voltage | 1200 V |
Area of application | Flexible use |
Drag Chain Tested | No |
Colour Outer Sheath | Grey |
LIYY PVC electronic cable is suitable for use in industrial applications such as scales and control panels to transmit measuring, control and voice signals.
Our supplier Stemmann-Technik (Wabtec Corporation) offers customer-specific cable reels for various applications. The selection includes a wide range of spring and motor cable reels for different purposes. The reels are designed according to customer requirements.
The food and beverage industries have placed high expectations on products and packages. OEM Automatic meets these expectations by expanding the range of its cable & connection technology product area with products developed especially for the needs of the food and beverage industry.
Junior Timer connectors are a popular choice for magnet valve electrical quick connectors. Molex MPM Junior Timer connector cables have been on the market for a long time, but now Molex has also introduced the new Molex MPM Junior Timer connector.
Delcon's CRA5 plug-in relay revolutionizes the control of difficult-to-handle DC loads. Inductive loads, frequent switching, and high DC voltages are a piece of cake for these relays.
Inxpect safety radars detect access or presence of operators in dangerous areas and also have the ability to dynamically set the detection and warning zones.
With the help of our technical department, we can offer efficient and comprehensive delivery of safety edges, ready for plug-and-play installation.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Nominal Voltage | ||
---|---|---|---|
![]()
LIYY 2x0,14 mm129
Art:
SAB03050214/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 3x0,14 mm129
Art:
SAB03050314/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 4x0,14 mm129
Art:
SAB03050414/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 5x0,14 mm129
Art:
SAB03050514/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 6x0,14 mm129
Art:
SAB03050614/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 7x0,14 mm129
Art:
SAB03050714/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 8x0,14 mm129
Art:
SAB03050814/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,14 mm129
Art:
SAB03051014/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,14 mm129
Art:
SAB03051214/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 14x0,14 mm129
Art:
SAB03051414/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 16x0,14 mm129
Art:
SAB03051614/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 20x0,14 mm129
Art:
SAB03052014/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 2x0,25 mm129
Art:
SAB03050225/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 3x0,25 mm129
Art:
SAB03050325/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 4x0,25 mm129
Art:
SAB03050425/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 5x0,25 mm129
Art:
SAB03050525/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 6x0,25 mm129
Art:
SAB03050625/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 7x0,25 mm129
Art:
SAB03050725/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 8x0,25 mm129
Art:
SAB03050825/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 10x0,25 mm129
Art:
SAB03051025/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,25 mm129
Art:
SAB03051225/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 14x0,25 mm129
Art:
SAB03051425/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 16x0,25 mm129
Art:
SAB03051625/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 20x0,25 mm129
Art:
SAB03052025/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 2x0,34 mm129
Art:
SAB03050234/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 3x0,34 mm129
Art:
SAB03050334/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 4x0,34 mm129
Art:
SAB03050434/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 5x0,34 mm129
Art:
SAB03050534/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 6x0,34 mm129
Art:
SAB03050634/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 7x0,34 mm129
Art:
SAB03050734/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 8x0,34 mm129
Art:
SAB03050834/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 10x0,34 mm129
Art:
SAB03051034/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,34 mm129
Art:
SAB03051234/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 14x0,34 mm129
Art:
SAB03051434/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 16x0,34 mm129
Art:
SAB03051634/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 20x0,34 mm129
Art:
SAB03052034/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 2x0,5 mm129
Art:
SAB03050250/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 3x0,5 mm129
Art:
SAB03050350/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 4x0,5 mm129
Art:
SAB03050450/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 5x0,5 mm129
Art:
SAB03050550/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 7x0,5 mm129
Art:
SAB03050750/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 8x0,5 mm129
Art:
SAB03050850/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 10x0,5 mm129
Art:
SAB03051050/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,5 mm129
Art:
SAB03051250/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 16x0,5 mm129
Art:
SAB03051650/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 2x0,75 mm129
Art:
SAB03050275/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 3x0,75 mm129
Art:
SAB03050375/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 4x0,75 mm129
Art:
SAB03050475/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 5x0,75 mm129
Art:
SAB03050575/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 6x0,75 mm129
Art:
SAB03050675/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 7x0,75 mm129
Art:
SAB03050775/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 8x0,75 mm129
Art:
SAB03050875/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 10x0,75 mm129
Art:
SAB03051075/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 12x0,75 mm129
Art:
SAB03051275/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 16x0,75 mm129
Art:
SAB03051675/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
| |
![]()
LIYY 20x0,75 mm129
Art:
SAB03052075/04K
Copied
|
Uo/U 0,14 mm2 = 350 V, ≥ 0,25 mm2 = 500 V
|
|
Select a variant in the list