• Over 25,000 products in stock
  • clock Stock items ordered before 15:00, will be dispatched on the same day
  • Read more about us
EFORE
EFORE

400W industrial power supplies

  • 12V, 24V, 28V, 36V and 48V DC outputs
  • High efficiency 94%
  • Different enclosure types from open to closed
  • 5V stand-by and 12V AUX outputs
  • 440W peak power 10s

Product description

Reliable, efficient and compact, Efore's DDP400 series of single output AC/DC power supplies are approved to the latest ITE safety standards and offer designers a choice of package types, including open frame, u-chassis, sealed, fan-cooled and perforated covers.

Variants

Articles Input voltage AC Input voltage ac min Input voltage ac max Supply Voltage DC Min Supply Voltage DC Max Output voltage Output Current Max Effect Length Width Height Weight IP Class Approvals Temperature Range From Temperature Range To Power Factor at 120 V AC, full load. Typical Power Factor at 230 V AC, full load. Typical Efficiency At 230 V AC, full load. Typical
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 164,2 mm 76 mm 37,7 mm 0,41 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 164,2 mm 76 mm 37,7 mm 0,41 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 164,2 mm 76 mm 37,7 mm 0,41 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 164,2 mm 76 mm 37,7 mm 0,41 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 166,5 mm 84,4 mm 40 mm 0,525 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 166,5 mm 84,4 mm 40 mm 0,525 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 166,5 mm 84,4 mm 40 mm 0,525 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 166,5 mm 84,4 mm 40 mm 0,525 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 28 V DC 14,3 A 400 W 166,5 mm 84,4 mm 40 mm 0,525 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 183 mm 84,4 mm 41 mm 0,685 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 183 mm 84,4 mm 41 mm 0,685 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 183 mm 84,4 mm 41 mm 0,685 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 183 mm 84,4 mm 41 mm 0,685 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 170,5 mm 84,4 mm 41 mm 0,575 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 170,5 mm 84,4 mm 41 mm 0,575 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 170,5 mm 84,4 mm 41 mm 0,575 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 170,5 mm 84,4 mm 41 mm 0,575 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 166,5 mm 84,4 mm 41 mm 0,67 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 166,5 mm 84,4 mm 41 mm 0,67 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 166,5 mm 84,4 mm 41 mm 0,67 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 166,5 mm 84,4 mm 41 mm 0,67 kg CB, CE, CSA 22.2, UL -20 °C 50 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 12 V DC 33,3 A 400 W 212 mm 83 mm 42 mm 1,3 kg IP67 CB, CE, CSA 22.2, UL -20 °C 70 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 24 V DC 16,7 A 400 W 212 mm 83 mm 42 mm 1,3 kg IP67 CB, CE, CSA 22.2, UL -20 °C 70 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 36 V DC 11,1 A 400 W 212 mm 83 mm 42 mm 1,3 kg IP67 CB, CE, CSA 22.2, UL -20 °C 70 °C 0,95 0,95 94 %
100-240 V AC 90 V AC 264 V AC 170 V DC 270 V DC 48 V DC 8,3 A 400 W 212 mm 83 mm 42 mm 1,3 kg IP67 CB, CE, CSA 22.2, UL -20 °C 70 °C 0,95 0,95 94 %
277/347/480 V AC 249 V AC 528 V AC 300 V DC 400 V DC 24 V DC 16,7 A 400 W 258 mm 93,6 mm 44,5 mm 1,9 kg IP67 CE, CSA 22.2, UL -35 °C 50 °C
277/347/480 V AC 249 V AC 528 V AC 300 V DC 400 V DC 36 V DC 11,1 A 400 W 258 mm 93,6 mm 44,5 mm 1,9 kg IP67 CE, CSA 22.2, UL -35 °C 50 °C
277/347/480 V AC 249 V AC 528 V AC 300 V DC 400 V DC 48 V DC 8,3 A 400 W 258 mm 93,6 mm 44,5 mm 1,9 kg IP67 CE, CSA 22.2, UL -35 °C 50 °C

Variant

DDP400-US12-OF
Power supply 100-240 V AC/12 V DC, 33,3 A

Specifications

Input voltage AC 100-240 V AC
Input voltage ac min 90 V AC
Input voltage ac max 264 V AC
Supply Voltage DC Min 170 V DC
Supply Voltage DC Max 270 V DC
Output voltage 12 V DC
Output Current Max 33,3 A
Effect 400 W
Length 164,2 mm
Width 76 mm
Height 37,7 mm
Weight 0,41 kg
Approvals CB, CE, CSA 22.2, UL
Temperature Range From -20 °C
Temperature Range To 50 °C
Power Factor at 120 V AC, full load. Typical 0,95
Power Factor at 230 V AC, full load. Typical 0,95
Efficiency At 230 V AC, full load. Typical 94 %
Contact us

Please contact us for more information.

Send e-mail