• Over 25,000 products in stock
  • clock Stock items ordered before 15:00, will be dispatched on the same day
  • Read more about us
DATASENSING

DATASENSING

Datalogic - Safety relay CSME

  • Cost effective safety relay
  • 3 NO safety relay outputs, need EDM control
  • 2 inputs for OSSD´s

Product description

Datalogic safety relay CSME is a low cost safety relay who can be used together with all SG and SE series light curtains that have EDM function (External Device Monitoring). CSME relay does not have internal monitoring so EDM control is compulsory.

By CSME safety relay the OSSD´s from safety light curtain can be changed to potential free relay contacts.

With proper EDM connection it maintain the same safety level as safety light curtain who is connected to CSME relay.



Connection example

Connection to SG4 safety light curtain

 

Technical Data

Supply voltage

24 V DC

Tolerance

+- 20 %

Rated power consumption

< 2 W max

Start power consumption

< 3 W max

Safe outputs

3 NO force quided relay contact + 1 NC contact for EDM

Max. switching current

6 A

Max. switching voltage

230/240 VAC, 300 VDC

Disconnection time

40 ms

Status indication

2 x LED

Ingress protection class:

IP40 (housing), IP20 (terminal block)

Operating temperature

-25 °C to +55 °C

Material

Housing: Polyamid PA 6.6 class V0 (UL94)

Weight

200 g

Dimensions (L x H x D)

111,5 x 99,0 x 22,5 mm

Mechanical endurance

> 10 millions operations

Electrical endurance

> 100.000 operations

Standard conformity

EN 60204-1, EN 954, EN 999, EN 1037, EN ISO 12100-1,
EN ISO 12100-2, EN 418, EN 60529, EN 61000-6-2,
EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-1, UL 508, CSA C22.2 n°14- 95

Directory conformity

2006/95/EC, 2006/42/EC, 2004/108/EC

Approval

Ce-marking, UL508 File number:E198865UL file E131787

 

Dimensions

Dimensions (L x H x D)

111.5 x 99.0 x 22.5 mm

 

Connection

Terminals


Terminal

Connection

EDM: (red)

24 VDC (power supply)

EDM: (yellow)

to EDM input (light curtain)

A2:

0 VDC (power supply)

OS1:

OSSD1 (from light curtain)

OS2:

OSSD2 (from light curtain)

13-14

NO safety relay output

23-24

NO safety relay output

33-34

NO safety relay output



Connection examples

Connection to SG4 safety light curtain

 

 

 

Order Numbers

Order no.

Description

Output

CSME-03VU24-Y14

Safety relay Datalogic CSME, 3 NO, 24 V DC
(EDM control is compulsory)

3 NO relay

 

Variant

CSME-03VU24-Y14
RELAY CSME-03VU24-Y14 EDM Type

spinner symbol