24 V dc UPS for external battery. 10 A

A DC-UPS system consists of a control unit, battery and power supply with suitable power for the application. In the event of a power outage, the battery is automatically switched in and supplies the connected loads. The control unit requires just (1) 12 V battery that then transforms the battery voltage up to 22.3 V dc. Two batteries do not need to be matched with one another and the output voltage does not follow the battery's discharge curve but is instead constant at 22.3 V. The battery capacity is utilized 100 % compared with two batteries connected in series, where one of the batteries is not fully charged. Two relay outputs indicate status; the module is ready (battery capacity >85 %) and the module is active (buffer mode). The control unit tests the battery's condition in cycles. When it is time to replace the battery, a relay output is activated (replace battery). At the front, optimized final charging voltage in relation to ambient temperature is selected. There are three available alternatives: 10°C, 25°C and 40°C. The buffer time can be set in different time ranges to save battery capacity. When choosing constant discharge, the output voltage will be active until the battery reaches deep discharge and the control unit then disconnects the battery. In the event of a battery fuse fault, the “ready” output is deactivated and a red LED lights on the control unit. The output is current-limited and turns itself off about 5 seconds after a short circuit to spare the battery and at the same time, avoid tripping the battery fuse. In the event of a short circuit in buffer mode, the module produces about 20 A, which helps trip any secondary fuses. Monitoring of the battery fuse and current limitation in the event of short circuits provides increased reliability and guarantees that the UPS will function after a short circuit. The input is galvanically isolated from the output side.


Battery holder for DIN rail

Power supply

  • Available for 7 and 24 Ah batteries
  • Puls DIN rail bracket
  • Wiring incl. 30 A fuse
  • Heavy duty terminal blocks
  • Quick and easy battery replacement

 

Read more
  • Requires just one 12 V dc battery
  • Selectable buffer times
  • Relay outputs for status
  • Optimized charging of battery

Selected variant

DC UPS 12/24VDC

DC UPS 12/24VDC

Art:

Selected variant

Specifications

Input Voltage From The Unit 24 V DC
Input Voltage From battery 12 V DC
Input voltage for battery connection 22,8 V DC
Input Current During Charging Of Aggregates 1,2 A
Type Power Supply DC-UPS
Output voltage min 12 V DC
Output voltage max 24 V DC
Output Current At 12 V DC 5 A
Output current at 24 V dc 10 A
Power Reduction Of 60 To 70 ° C 5 W/°C
Output Voltage at Battery 22,25
Output Voltage Normal Operation 24 V DC
Output Voltage At Buffering 22,25 V DC
Output current for battery operation max 10 A (15 A @ 5 s)
Output Current During Normal Operation Via The Unit Max 15 A
Ripple. max 20 mV pp
Temperature Range Without Derating From -25 °C
Temperature Range Without Derating To 50 °C
Efficiency 97,5 %
Life span 114 000 h @ 10 A, 40 °C
MTBF (IEC 61709) 788 000 h @ 10 A, 40 °C
Width 49 mm
Height 124 mm
Depth 117 mm
Weight 0,65 kg
Approvals CB, CE, CSA, CSA US, EX, IECEx, UL
Material Protection Aluminium
IP Class IP20
Charging The Battery Type 1,5 A
Voltage Level Of The Connection Of The Battery 22,3 V DC
Permitted Battery Sizes 3,9-40 Ah

Product description

A DC-UPS system consists of a control unit, battery and power supply with suitable power for the application. In the event of a power outage, the battery is automatically switched in and supplies the connected loads. The control unit requires just (1) 12 V battery that then transforms the battery voltage up to 22.3 V dc. Two batteries do not need to be matched with one another and the output voltage does not follow the battery's discharge curve but is instead constant at 22.3 V. The battery capacity is utilized 100 % compared with two batteries connected in series, where one of the batteries is not fully charged. Two relay outputs indicate status; the module is ready (battery capacity >85 %) and the module is active (buffer mode). The control unit tests the battery's condition in cycles. When it is time to replace the battery, a relay output is activated (replace battery). At the front, optimized final charging voltage in relation to ambient temperature is selected. There are three available alternatives: 10°C, 25°C and 40°C. The buffer time can be set in different time ranges to save battery capacity. When choosing constant discharge, the output voltage will be active until the battery reaches deep discharge and the control unit then disconnects the battery. In the event of a battery fuse fault, the “ready” output is deactivated and a red LED lights on the control unit. The output is current-limited and turns itself off about 5 seconds after a short circuit to spare the battery and at the same time, avoid tripping the battery fuse. In the event of a short circuit in buffer mode, the module produces about 20 A, which helps trip any secondary fuses. Monitoring of the battery fuse and current limitation in the event of short circuits provides increased reliability and guarantees that the UPS will function after a short circuit. The input is galvanically isolated from the output side.


Battery holder for DIN rail

Power supply

  • Available for 7 and 24 Ah batteries
  • Puls DIN rail bracket
  • Wiring incl. 30 A fuse
  • Heavy duty terminal blocks
  • Quick and easy battery replacement

 

Accessories

Related products

Contact us

Please contact us for more information.

Send e-mail Send e-mail

Logo

Cookies on oem.ee

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

Functional cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analytics cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.