DELCON

Accessories

Part Number

Description

Notes

FC10-cables

Normal flat cables, 10 pole.

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

FC20-cables

Normal flat cables, 20 pole.

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

RC10-cables

Round flat cables, 10 pole.

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected.

RC10X-cables

Round flat cable, 10 pole, single wires

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC.

RC20-cables

Round flat cables, 20 pole

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

RC20X-cables

Round flat cable, 20 pole, single wires

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC. 

 

PCB Sockets

• PCU 1 - pcb socket for all plug-in SL-relays

• PCI 1 - pcb socket for plug-in SL-input relays

• PCO 1 - pcb socket for plug-in SL-output relays

• 6,3 A continuous current/contact

• 0...250/400 VAC/DC nominal voltages

• cULus Listed (UL and CSA)

• CE (LVD)

 

Physical dimensions and other data

 

Breakdown voltage I/O, min.

4600 VACrms

Air/creepage distance I/O, min.

8 mm

Material

UL 94 V-0

Weight, typ.

4.5 g

Current/contact, max.

6.3 A rms

Temperature

storage

operation

 

-40°C to +70°C

-40°C to +70°C

 

Nominal dimensions in mm. Illustrated is PCU 1.

PCI 1 without contact #3.

PCO 1 without contact #5.

 

 

When using as mounting sockets for SL series relays the assembling distance for the sockets should be 13 mm or more due to measure tolerances and cooling the relays.

 

Jumper

Part Number

Description

JUMPER16-13

Chaining bridge 16 pin, 13 mm pitch

 

Read more
  • Cables
  • PCB Sockets
  • Jumper
  • Converters

Selected variant

Selected variant

Specifications

There is no technical data filled. Please contact sales.

Product description

Part Number

Description

Notes

FC10-cables

Normal flat cables, 10 pole.

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

FC20-cables

Normal flat cables, 20 pole.

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

RC10-cables

Round flat cables, 10 pole.

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected.

RC10X-cables

Round flat cable, 10 pole, single wires

The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC.

RC20-cables

Round flat cables, 20 pole

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. 

RC20X-cables

Round flat cable, 20 pole, single wires

The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC. 

 

PCB Sockets

• PCU 1 - pcb socket for all plug-in SL-relays

• PCI 1 - pcb socket for plug-in SL-input relays

• PCO 1 - pcb socket for plug-in SL-output relays

• 6,3 A continuous current/contact

• 0...250/400 VAC/DC nominal voltages

• cULus Listed (UL and CSA)

• CE (LVD)

 

Physical dimensions and other data

 

Breakdown voltage I/O, min.

4600 VACrms

Air/creepage distance I/O, min.

8 mm

Material

UL 94 V-0

Weight, typ.

4.5 g

Current/contact, max.

6.3 A rms

Temperature

storage

operation

 

-40°C to +70°C

-40°C to +70°C

 

Nominal dimensions in mm. Illustrated is PCU 1.

PCI 1 without contact #3.

PCO 1 without contact #5.

 

 

When using as mounting sockets for SL series relays the assembling distance for the sockets should be 13 mm or more due to measure tolerances and cooling the relays.

 

Jumper

Part Number

Description

JUMPER16-13

Chaining bridge 16 pin, 13 mm pitch

 

Accessories

Related

Articles

Selected variant

Select a variant in the list

Contact us

Please contact us for more information.

Send e-mail Send e-mail