DELCON
Part Number | Description | Notes |
FC10-cables | Normal flat cables, 10 pole. | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
FC20-cables | Normal flat cables, 20 pole. | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC10-cables | Round flat cables, 10 pole. | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC10X-cables | Round flat cable, 10 pole, single wires | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC. |
RC20-cables | Round flat cables, 20 pole | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC20X-cables | Round flat cable, 20 pole, single wires | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC. |
• PCU 1 - pcb socket for all plug-in SL-relays
• PCI 1 - pcb socket for plug-in SL-input relays
• PCO 1 - pcb socket for plug-in SL-output relays
• 6,3 A continuous current/contact
• 0...250/400 VAC/DC nominal voltages
• cULus Listed (UL and CSA)
• CE (LVD)
Physical dimensions and other data | | |
Breakdown voltage I/O, min. | 4600 VACrms | |
Air/creepage distance I/O, min. | 8 mm | |
Material | UL 94 V-0 | |
Weight, typ. | 4.5 g | |
Current/contact, max. | 6.3 A rms | |
Temperature storage operation |
-40°C to +70°C -40°C to +70°C | |
Nominal dimensions in mm. Illustrated is PCU 1. PCI 1 without contact #3. PCO 1 without contact #5.
|
When using as mounting sockets for SL series relays the assembling distance for the sockets should be 13 mm or more due to measure tolerances and cooling the relays.
Jumper
Part Number | Description |
JUMPER16-13 | Chaining bridge 16 pin, 13 mm pitch |
Part Number | Description | Notes |
FC10-cables | Normal flat cables, 10 pole. | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
FC20-cables | Normal flat cables, 20 pole. | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC10-cables | Round flat cables, 10 pole. | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC10X-cables | Round flat cable, 10 pole, single wires | The cables are used to connect PLC to the multichannel mounting base. 10-pole cable is used to connect 8-channel mounting base to the PLC. |
RC20-cables | Round flat cables, 20 pole | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC adapter. On each PLC adapter page can be seen which mounting bases can be connected. |
RC20X-cables | Round flat cable, 20 pole, single wires | The cables are used to connect PLC to the multichannel mounting base. 20-pole cable is used to connect 16-channel mounting base to the PLC. |
• PCU 1 - pcb socket for all plug-in SL-relays
• PCI 1 - pcb socket for plug-in SL-input relays
• PCO 1 - pcb socket for plug-in SL-output relays
• 6,3 A continuous current/contact
• 0...250/400 VAC/DC nominal voltages
• cULus Listed (UL and CSA)
• CE (LVD)
Physical dimensions and other data | | |
Breakdown voltage I/O, min. | 4600 VACrms | |
Air/creepage distance I/O, min. | 8 mm | |
Material | UL 94 V-0 | |
Weight, typ. | 4.5 g | |
Current/contact, max. | 6.3 A rms | |
Temperature storage operation |
-40°C to +70°C -40°C to +70°C | |
Nominal dimensions in mm. Illustrated is PCU 1. PCI 1 without contact #3. PCO 1 without contact #5.
|
When using as mounting sockets for SL series relays the assembling distance for the sockets should be 13 mm or more due to measure tolerances and cooling the relays.
Jumper
Part Number | Description |
JUMPER16-13 | Chaining bridge 16 pin, 13 mm pitch |
Delcon's CRA5 plug-in relay revolutionizes the control of difficult-to-handle DC loads. Inductive loads, frequent switching, and high DC voltages are a piece of cake for these relays.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
Can you distinguish between a bifurcated contact and a normal contact at a glance?
The Lütze LOCC-Box is an intelligent electronic overcurrent protection device that provides reliable protection for 12/24 V DC systems in a narrow housing measuring just 8.1 mm. Integrated + and - terminals save space on the DIN rail.
DF Electric is specialized in the manufacturing of fuse links, fuse holders and control transformers since 1987. Presently the company is leading the Spanish market and is also very active in many export markets due to its competitive range of products.