DELCON
The relays are used as an interface between AC sensors and control systems. The integrated interference protection provides reliable operation even in very demanding electrical environments. Thanks to interference protection, signal cables can be run alongside power cables on, for example, cable racks for more than 1.5 km without capacitive cross-talk affecting relays. The relays have no mechanical parts, which provides very reliable application. The CRP models are especially designed for connecting to 2-wire sensors that generate leakage current. The CRP relays are blind to leakage currents up to 3.5 mA.
AC input module | ||
Ambient temperature is defined as the temperature in direct proximity to the relays. | ||
Ambient temperature | Applies to | Limitations |
-25°C to +40°C | All input relays | None |
+40°C to +55°C | 120 V ac and 230 V ac relays | Only every other module should be constantly activated when the relays are mounted beside one another |
+55°C to +70°C | Relays with voltages from 48-230 V ac | If the modules are in the activated state the majority of the time, the modules must be 12.5 mm apart. On a mounting base, every other position must be empty |
| Approvals | CE, UL |
|---|---|
| Input | 4 kΩ |
| Input Voltage Nom | 24 |
| Load Current | 50 mA |
| Load Voltage DC max | 60 V |
| Number of poles | 1 |
| Power Consumption max | 15 mA |
| Release Time | 60 ms |
| Response Time | 20 ms |
| Switching Voltage | 16 V |
| Temperature range bearing, from | -40 °C |
|---|---|
| Temperature range bearing, to | 70 °C |
| Temperature range from | -40 °C |
| Temperature range to | 70 °C |
| Tripping voltage | 14 V |
| Weight | 40 g |
| Width | 12.5 mm |
| Voltage Drop | 0.2 V |
| Voltage Drop Over The Semi-Conductor at Imax | 0.4 V |
The relays are used as an interface between AC sensors and control systems. The integrated interference protection provides reliable operation even in very demanding electrical environments. Thanks to interference protection, signal cables can be run alongside power cables on, for example, cable racks for more than 1.5 km without capacitive cross-talk affecting relays. The relays have no mechanical parts, which provides very reliable application. The CRP models are especially designed for connecting to 2-wire sensors that generate leakage current. The CRP relays are blind to leakage currents up to 3.5 mA.
AC input module | ||
Ambient temperature is defined as the temperature in direct proximity to the relays. | ||
Ambient temperature | Applies to | Limitations |
-25°C to +40°C | All input relays | None |
+40°C to +55°C | 120 V ac and 230 V ac relays | Only every other module should be constantly activated when the relays are mounted beside one another |
+55°C to +70°C | Relays with voltages from 48-230 V ac | If the modules are in the activated state the majority of the time, the modules must be 12.5 mm apart. On a mounting base, every other position must be empty |
Delcon's CRA5 plug-in relay revolutionizes the control of difficult-to-handle DC loads. Inductive loads, frequent switching, and high DC voltages are a piece of cake for these relays.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
Can you distinguish between a bifurcated contact and a normal contact at a glance?
Thanks to their loop design, LOOP heating elements offer excellent heating performance and ensure optimal heat distribution. Read more now!
TER - Tecno Elettrica Ravasi, is our Italian supplier specializing in the manufacture of control stations. TER has over 60 years of experience in the manufacture of control stations.