These relays offer a broad range of power ratings which makes them suitable for diverse applications. Their high reliability and efficient design have made of them a market favorite for many years.
- Current ratings of 35 and 45 amps
- Output voltage rating: 48-600 VAC
- Direct Bond Copper (DBC) Substrate
- LED input status indicator
- UL 508 Endurance Rating for Enhanced Reliability
- UL/CSA/TUV Approved, CE Compliant
- Built-in overvoltage protection
- DIN Rail or Panel Mount
- Zero voltage or Instantaneous turn-on output
Technical Data
Output Specifications (1)
Description | GNR35 | GNR45 |
Operating Voltage (47-440Hz) [Vrms] | 48-600 | 48-600 |
Transient Overvoltage [Vpk, t=1 min.] | 1100 | 1100 |
Maximum Load Current [Arms] | 35 | 45 |
Minimum Load Current [Arms] | 0.1 | 0.1 |
Maximum Off-State Leakage Current @ Rated Voltage [mArms] | 0.25 | 0.25 |
Static Off-State dv/dt ( V/μsec, Ta=25°C) (2) | 500 | 500 |
1 Second Surge Current (Apk Ta=25°C) 50/60 Hz | 130 | 150 |
Forward Voltage Drop (Vpk @ max, Ta=25°C) | 1.35 | 1.35 |
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk] | 668/700 | 716/750 |
Maximum I² t for Fusing (50/60Hz, 1/2 cycle ) [A² sec] | 2230/2020 | 2562/2334 |
HP Ratings at 120V / FLC [Arms] | 1.5/20 | 1.5/20 |
HP Ratings at 240V / FLC [Arms] | 3/17 | 3/17 |
HP Ratings at 480V / FLC [Arms] | 5/14 | 5/14 |
Min/Max stranded wire | 16/8 AWG | 16/8 AWG |
Min/Max solid wire | 16/10 AWG | 16/10 AWG |
Input Specifications (1)
Description | GNRxxDx | GNRxxBx | GNRxxAx |
Control Voltage Range (3) | 4.0-32 VDC | 90-140 Vrms | 180-280 Vrms |
Minimum Turn-On Voltage | 4.0 VDC | 90 Vrms | 180 Vrms |
Must Turn-Off Voltage | 1.0 VDC | 10 Vrms | 10 Vrms |
Minimum Input Current (for on-state) | 16 mA | 5 mArms | 6 mA |
Maximum Input Current | 19 mA | 6 mArma | 8 mA |
Input Resistance | Current Regulated | Current Regulated | Current Regulated |
Maximum Turn-Off Time [msec] | 1/2 Cycle | 20 | 20 |
Maximum Turn-On Time [msec] (4) | 1/2 Cycle | 30 | 30 |
Min/Max stranded/solid wire | 24/16 AWG | 24/16 AWG | 24/16 AWG |
General Specifications (1)
Description | Parameters |
Ambient Operating Temperature Range (3) | -20 to 80°C |
Ambient Storage Temperature Range | -40 to 100°C |
Dielectric Strength, Input to Output (50/60Hz) | 4000 Vrms |
Dielectric Strength, Input/Output to Ground (50/60Hz) | 2500 Vrms |
Maximum Capacitance, Input/Output | 8 pF |
Housing Material | UL 94V0 (self extinguishing) |
Input Status Indicator | Green LED |
Weight (typical) | 14.1 oz (400g) |
General Notes
(1) All parameters at 25°C unless otherwise specified.
(2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
(3) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60°C.
(4) Turn-on time for Instantaneous version (R suffix) is 0.1 msec (for DC control only).
(5) TUV Certification according to EN 60950-1/A1:2010
Mechanical Specifications (1)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Contactor Configuration | Relay Configuration |
 | 
|
Wiring Diagram
Thermal Derate Information
Agency Approvals
Designed in accordance with the requirements of IEC 62314
cRU UK E79183 SA LR 38595 TDV (5) CE RoSH
EMC Compatibility
Designed in accordance with the requirements of IEC 62314
IEC 60068-2-6 35mm/10-55Hz
IEC 62314
IEC 60068-2-27 15G / 11ms
IEC 61000-4-2 Level 3 Electrostatic Discharge
IEC 61000-4-3 Level 3 Radiated Electromagnetic Noise
IEC 61000-4-4 Level 3 Immunity to Electrically Fast Transients
IEC 61000-4-5 Level 3 Immunity to Electrical Surges
IEC 61000-4-6 Level 3 Conducted Electromagnetic Noise
CISPR 11 Class A Conducted and Radiated Noise for Industrial Environments
Part Numbers
Product Selection
Control Voltage | 35A | 45A |
4-32 VDC | GNR35DHZ | GNR45DHZ |
90-140 VAC | GNR35BHZ | GNR45BHZ |
180-280 VAC | GNR35AHZ | GNR45AHZ |