CROUZET CONTROL

Plug In Timer 11 Pin

Syr-Line Series

SyrLine, the new specialised range from Crouzet. Aimed to satisfy the most unique requirements of any application by innovations in design, engineering and develipment.

The new family of 11 pin plug-in analog timers - multifunction or monofunction, with a wide time range, and with all the classic timing functions.

Read more
  • Single or Multi-Function
  • Multi time range 0.5 sec - 10 days
  • Universal supply voltage 12-240Vac/dc
  • 2 x 10A rated relay contacts

Selected variant

Selected variant

Specifications

Approvals CE, cULus, REACH, RoHS
Breaking capacity 2500 VA / 300W
Depth 95,6 mm
Function A - Delay on energisation, Ac - Timing after closing and opening of control contact, Ad - Delay on energisation (no reset), At - Timing on energisation with memory, B - Timing on impulse (one shot), Bw - Pulse output (adjustable), C - Timing after impulse, D - Symmetrical flashing, Di - Symmetrical flashing, H - Timing on energisation - pulse output, Ht - Delay on energisation with memory
Height 53 mm
IP Class IP40
Mounting 11-pin socket
Multifunction Yes
Output Relay 2 pole C/O
Power Consumption 1,5 W
Repeatability 0,5 %
Response Closing 40 ms
Response From Stroke 120 ms
Supply voltage 12-240V AC/DC
Switching Current Max 10 A
Temperature range bearing, from -40 °C
Temperature range bearing, to 70 °C
Temperature range from -20 °C
Temperature range to 60 °C
Time Range 0,5-10s, 0,05-1min, 0,5-10min, 0,05-1h, 0,5-10h, 0,05-1d, 0,5-10d
Width 35 mm

Measurements and connections

Technical illustrations

Product description

SyrLine, the new specialised range from Crouzet. Aimed to satisfy the most unique requirements of any application by innovations in design, engineering and develipment.

The new family of 11 pin plug-in analog timers - multifunction or monofunction, with a wide time range, and with all the classic timing functions.

Accessories

Related

Articles Function Multifunction
A - Delay on energisation, Ac - Timing after closing and opening of control contact, Ad - Delay on energisation (no reset), At - Timing on energisation with memory, B - Timing on impulse (one shot), Bw - Pulse output (adjustable), C - Timing after impulse, D - Symmetrical flashing, Di - Symmetrical flashing, H - Timing on energisation - pulse output, Ht - Delay on energisation with memory
Yes
A - Delay on energisation, At - Timing on energisation with memory
No
C - Timing after impulse
No
L - Asymmetrical flashing, Li - Asymmetrical flashing
No

Selected variant

Select a variant in the list

Contact us

Please contact us for more information.

Send e-mail Send e-mail