Control relay for monitoring 3-phase networks without neutral. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. Monitors under-voltage between the phases that can be set between -2 % and -20 % of Un (measurement voltage) and over-voltage that can be set between 2 % and 20 % of Un. Time delay Tt prevents relay change-over in the event of temporary disturbances and is adjustable between 0.3-30 s. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Over-/under-voltage |
1: Over-voltage |
2: Hysteresis |
3: Under-voltage |
4: L1, L2, L3 |
5: Relay |
6: Limit value with time delay for over-/under-voltage |
| Approvals | CE, CSA, RoHS, UL |
|---|---|
| Breaking capacity | 5A, 250V AC/DC |
| IP Class Connection | IP20 |
| IP Class Housing | IP30 |
| Lower Limit | -2 - -20% |
| Output | 2x Relay |
| Selection of rated voltage | 208, 220, 380, 400, 415, 440, 480V |
| Supply voltage | 3 x 208-480V AC |
| Temperature range bearing, from | -40 °C |
| Temperature range bearing, to | 70 °C |
|---|---|
| Temperature range from | -20 °C |
| Temperature range to | 50 °C |
| Time Delay On Crossing The Threshold | 0,3-30s |
| Time Delay Start | 0.5 s |
| Upper Limit | 2 - 20% |
| Weight | 80 g |
Control relay for monitoring 3-phase networks without neutral. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. Monitors under-voltage between the phases that can be set between -2 % and -20 % of Un (measurement voltage) and over-voltage that can be set between 2 % and 20 % of Un. Time delay Tt prevents relay change-over in the event of temporary disturbances and is adjustable between 0.3-30 s. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Over-/under-voltage |
1: Over-voltage |
2: Hysteresis |
3: Under-voltage |
4: L1, L2, L3 |
5: Relay |
6: Limit value with time delay for over-/under-voltage |
Delcon's CRA5 plug-in relay revolutionizes the control of difficult-to-handle DC loads. Inductive loads, frequent switching, and high DC voltages are a piece of cake for these relays.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
Can you distinguish between a bifurcated contact and a normal contact at a glance?
TER - Tecno Elettrica Ravasi, is our Italian supplier specializing in the manufacture of control stations. TER has over 60 years of experience in the manufacture of control stations.
Thanks to their loop design, LOOP heating elements offer excellent heating performance and ensure optimal heat distribution. Read more now!