CROUZET CONTROL
Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indication) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). In the event of an asymmetry fault, the relay triggers an alarm (drops out) after the time delay Tt that is set at the front by the user. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Approvals | CSA, GL, RoHS, UL |
---|---|
Breaking capacity | 5A, 250V AC/DC |
IP Class Connection | IP20 |
IP Class Housing | IP30 |
Output | Relay |
Selection of rated voltage | 208, 220, 380, 400, 415, 440, 480 V |
Supply voltage | 3 x 208-480V AC |
Temperature range bearing, from | -40 °C |
Temperature range bearing, to | 70 °C |
---|---|
Temperature range from | -20 °C |
Temperature range to | 50 °C |
Time Delay Alarm | 0,2 s |
Time Delay On Crossing The Threshold | 0,1-10s |
Time Delay Start | 0,5 s |
Weight | 80 g |
Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indication) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). In the event of an asymmetry fault, the relay triggers an alarm (drops out) after the time delay Tt that is set at the front by the user. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
Can you distinguish between a bifurcated contact and a normal contact at a glance?
The need for flexible, modular systems shapes machine and system engineering. Decentralization of the system components has proven to be an important factor for success.
The PIANO PIC series is designed for applications that require reliable DIN rail power supplies, which are focused to deliver the most widely required customer functionalities. Our PIC units offer this simplicity without making compromises on PULS’ renowned qualities; efficiency, service lifetime, reliability and size.
The new WADI product family by Jacob features a completely redesigned gland rubber, which allows extensive sealing and tightening area.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | ||
---|---|---|
MWA PHASE CONTROL RELAY
Art:
84873024
Copied
|
|
Select a variant in the list