• Over 25,000 products in stock
  • clock Stock items ordered before 15:00, will be dispatched on the same day
  • Read more about us
CONTA-CLIP

CONTA-CLIP

Installation terminals - FRKI

FRKI

  • Compact
  • Quick & easy installation
  • Polyamide 6.6-V0

Product description

The FNT neutral disconnect terminals feature an integral mounting post for attaching the 10x3-mm neutral busbar.

No additional plates or fixings are required,  as a secure contact to the busbar is made using the

no-screw slider for the neutral conductor.

With the FSLI protective earth terminals, the PE potential is connected via the PE foot (which contacts the DIN rail on both sides).

Solid wires and flexible wires with wire-end ferrules can be inserted into the connection mechanism without the need for tools.

The pressure spring opens automatically when the wire is inserted; this ensures a secure contact with the busbar.

A standard screwdriver can be used to open the clamp for release and for the insertion of stranded wire without ferrules.

This range can also be combined with the FDLIS three-level installation terminal range.

The one-level terminals – FRKI, FSLI, and FNT – can be used in combination with the three-level FDLIS installation terminals, as the height of the neutral busbar is identical in both versions.

Where the neutral busbar is not being used with the 16mm terminals, there is the FRK16 in the standard range, this has a central din rail mounting foot and provides a symmetrical layout.

 

Number of variants matching filter 19/19 |

Variants

Articles Approvals Color Connections Country of origin Cross connect channels Cross section single wire from Cross section single wire to Cross section stranded wire from Cross section stranded wire to Cross section stranded with ferrule from Cross section stranded with ferrule to Cross-Section CSA test standard CSAus test standard cUL test standard EAC test standard Height Height TS 35/7.5 KEMA KEUR test standard Length Pack Size Plug gauge acc. EN 60 947-1 Rated Current CSA Rated current CSAus Rated current cUL Rated Current IEC Rated Current To UL Rated impulse voltage Rated wire cross section from (AWG) Rated wire cross section to (AWG) Rated voltage CSAus Rated voltage cUL Rated Voltage IEC Rated Voltage To UL Stripping Length UL test standard Weight Width Voltage CSA
CSA, CSA US, KEMA KUR, EAC Beige 2 BG 2 0,5 mm² 6 mm² 0,6 mm² 6 mm² 0,5 mm² 4 mm² 4 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 37,5 mm 38,5 mm EN 60947-7-1:2009 52,5 mm 100 A4 28 A 28 A 32 A 8 kV 20 10 600 V 800 V 12 mm 8,25 g 5,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Blue 2 BG 2 0,5 mm² 6 mm² 0,6 mm² 6 mm² 0,5 mm² 4 mm² 4 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 37,5 mm 38,5 mm EN 60947-7-1:2009 52,5 mm 100 A4 28 A 28 A 32 A 8 kV 20 10 600 V 800 V 12 mm 8,25 g 5,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Orange 2 BG 2 0,5 mm² 6 mm² 0,6 mm² 6 mm² 0,5 mm² 4 mm² 4 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 37,5 mm 38,5 mm EN 60947-7-1:2009 52,5 mm 100 A4 28 A 28 A 32 A 8 kV 20 10 600 V 800 V 12 mm 8,25 g 5,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Green/yellow 2 BG 1 0,5 mm² 6 mm² 0,6 mm² 6 mm² 0,5 mm² 4 mm² 4 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 37,5 mm 38,5 mm EN 60947-7-2:2009 52,5 mm 100 A4 20 10 12 mm 11,25 g 5,1 mm
KEMA KUR Blue 1 BG 1 0,5 mm² 6 mm² 0,6 mm² 6 mm² 0,5 mm² 4 mm² 4 mm² 41,5 mm 42,5 mm EN 60947-7-1:2009 64 mm 100 A4 32 A 8 kV 20 10 250 V 12 mm 9,25 g 5,1 mm
CSA, CSA US, KEMA KUR, EAC Beige 2 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 39,8 mm 40,5 mm EN 60947-7-1:2009 56,5 mm 100 A5 44 A 44 A 57 A 8 kV 22 10 600 V 800 V 12 mm 14,25 g 8,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Blue 2 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 39,8 mm 40,5 mm EN 60947-7-1:2009 56,5 mm 100 A5 44 A 44 A 57 A 8 kV 22 10 600 V 800 V 12 mm 14,25 g 8,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Orange 2 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 39,8 mm 40,5 mm EN 60947-7-1:2009 56,5 mm 100 A5 44 A 44 A 57 A 8 kV 22 10 600 V 800 V 12 mm 14,25 g 8,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Red 2 CZ 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 39,8 mm 40,5 mm EN 60947-7-1:2009 56,5 mm 100 A5 44 A 44 A 57 A 8 kV 22 10 600 V 800 V 12 mm 14,25 g 8,1 mm 600 V
CSA, CSA US, KEMA KUR, EAC Green/yellow 2 BG 1 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 UL 1059 TR ZU 004/2011 39,8 mm 40,5 mm EN 60947-7-2:2009 56,5 mm 100 A5 22 10 12 mm 20,25 g 8,1 mm
KEMA KUR Blue 1 BG 1 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² 39,8 mm 40,5 mm EN 60947-7-1:2009 67,5 mm 100 A5 57 A 8 kV 22 10 250 V 12 mm 16,25 g 8,1 mm
EAC Beige 3 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 TR ZU 004/2011 39,8 mm EN 60947-7-1:2009 82,4 mm 50 A3 600 A 57 A 44 A 8 kV 16 8 44 V 800 V 600 V 12 mm UL 1059 27,09 g 8,1 mm
EAC Blue 3 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 TR ZU 004/2011 39,8 mm EN 60947-7-1:2009 82,4 mm 50 A3 600 A 57 A 44 A 8 kV 16 8 44 V 800 V 600 V 12 mm UL 1059 27,09 g 8,1 mm
EAC Orange 3 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 TR ZU 004/2011 39,8 mm EN 60947-7-1:2009 82,4 mm 50 A3 600 A 57 A 44 A 8 kV 16 8 44 V 800 V 600 V 12 mm UL 1059 27,09 g 8,1 mm
EAC Green/yellow 3 BG 2 1,5 mm² 10 mm² 1,5 mm² 10 mm² 1,5 mm² 10 mm² 10 mm² C22.2 No 158 TR ZU 004/2011 39,8 mm EN 60947-7-2:2009 82,4 mm 50 A3 16 8 12 mm UL 1059 33,87 g 8,1 mm
EAC Beige 2 CZ 2 2,5 mm² 25 mm² 2,5 mm² 25 mm² 2,5 mm² 16 mm² 16 mm² C22.2 No 158 TR ZU 004/2011 48 mm 49 mm EN 60947-7-1:2009 72,4 mm 50 A7 600 A 76 A 75 A 8 kV 14 4 75 V 1000 V 600 V 18 mm UL 1059 17,8 g 12,1 mm
EAC Blue 2 CZ 2 2,5 mm² 25 mm² 2,5 mm² 25 mm² 2,5 mm² 16 mm² 16 mm² C22.2 No 158 TR ZU 004/2011 48 mm 49 mm EN 60947-7-1:2009 72,4 mm 50 A7 600 A 76 A 75 A 8 kV 14 4 75 V 1000 V 600 V 18 mm UL 1059 17,8 g 12,1 mm
EAC Orange 2 CZ 2 2,5 mm² 25 mm² 2,5 mm² 25 mm² 2,5 mm² 16 mm² 16 mm² C22.2 No 158 TR ZU 004/2011 48 mm 49 mm EN 60947-7-1:2009 72,4 mm 50 A7 600 A 76 A 75 A 8 kV 14 4 75 V 1000 V 600 V 18 mm UL 1059 17,8 g 12,1 mm
EAC Green/yellow 2 CZ 1 2,5 mm² 25 mm² 2,5 mm² 25 mm² 2,5 mm² 16 mm² 16 mm² C22.2 No 158 TR ZU 004/2011 48 mm 49 mm EN 60947-7-2:2009 72,4 mm 50 A7 14 4 18 mm UL 1059 44,7 g 12,1 mm

Variant

3276.2

3276.2
FRKI 2.5-4 Beige, 4mm² Installation feed through, push-in

spinner symbol

Specifications

Approvals CSA, CSA US, KEMA KUR, EAC
Color Beige
Connections 2
Contamination degree 3
Country of origin BG
Cross connect channels 2
Cross section single wire from 0,5 mm²
Cross section single wire to 6 mm²
Cross section stranded wire from 0,6 mm²
Cross section stranded wire to 6 mm²
Cross section stranded with ferrule from 0,5 mm²
Cross section stranded with ferrule to 4 mm²
Cross-Section 4 mm²
CSA test standard C22.2 No 158
CSAus test standard UL 1059
EAC test standard TR ZU 004/2011
Flamklass UL94-V0
Height 37,5 mm
Height TS 35/7.5 38,5 mm
Insulation Material Polyamide 6.6
KEMA KEUR test standard EN 60947-7-1:2009
Length 52,5 mm
Mounting TS 35/7,5
Number of levels 1
Operating temperature from -40 °C
Operating temperature to 120 °C
Overvoltage category III
Pack Size 100
Plug gauge acc. EN 60 947-1 A4
Rated Current CSA 28 A
Rated current CSAus 28 A
Rated Current IEC 32 A
Rated impulse voltage 8 kV
Rated wire cross section from (AWG) 20
Rated wire cross section to (AWG) 10
Rated voltage CSAus 600 V
Rated Voltage IEC 800 V
Stripping Length 12 mm
Tariff code 85369010
Weight 8,25 g
Width 5,1 mm
Voltage CSA 600 V
Contact us

Please contact us for more information.

Send e-mail Send e-mail