CONTA-CLIP
Test-disconnect terminals are mainly used for power network, electricity generation and supply applications.
They are perfect for the wide variety of switching demands in the current-transformer secondary circuits that are common in these types of applications.
Current transformers must always have a closed secondary circuit, for use when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
All versions provide touch-safe protection in compliance with DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
In all versions, the STBI 19/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
Cross-switches QVSI
The VH 19 connecting sleeves and the BS 25 screws or STB 19/4 L socket plugs are required for fastening the QVSI cross-switches above the terminal block. The cross-switches are available from 2 to 10 poles.
Cross-switches QSBI
The QSBI internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
Mounting screw BS 25
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVSI cross-switches.
Switch lock PTK-SP
The PTK-SP switch lock is mounted over the slider on the SPTK terminals. It keeps the partition screws from being accidentally touched by a screwdriver.
Insulated socket plugs STBI 19/4 L
The STBI 19/4 L socket plugs can be screwed into the inside cross-connection channels. They are used together with the VH 19 connecting sleeves to establish contact with the QVSI cross-switches. They are also used to hold the PS 4 test plugs or conventional (4 mm) insulated test plugs.
Short-circuit plug KS-SQI
The KS-SQI short-circuit plugs are used to make pluggable cross-connections between the SPTK terminals in the outer cross-connection channels. The plugs can also be put in the built-in park position of the SPTK terminals when not in use. The short-circuit plugs are available from 2 to 5 poles.
Cross-connector SQI 6
The SQI cross-connector is used to make a pluggable cross-connection between the SPTK terminals in the outer cross-connection channels. The cross-connectors can also be put in the built-in park position of the SPTK terminals when not in use. The cross-connectors are available from 2 to 30 poles.
Approvals | UL, cUL, KEMA KUR |
---|---|
Color | Beige |
Connections | 2 |
Contamination degree | 3 |
Country of origin | CZ |
Cross connect channels | 4 |
Cross section single wire from | 0,2 mm² |
Cross section single wire to | 10 mm² |
Cross section stranded wire from | 0,2 mm² |
Cross section stranded wire to | 10 mm² |
Cross section stranded with ferrule from | 0,2 mm² |
Cross section stranded with ferrule to | 6 mm² |
Cross-Section | 6 mm² |
cUL test standard | C22.2 No 158 |
Flamklass | UL94-V0 |
Height TS 35/7.5 | 47 mm |
Insulation Material | Polyamide 6.6 |
KEMA KEUR test standard | EN 60947-7-1:2009 |
Length | 93 mm |
Mounting | TS 35/7,5 |
Number of levels | 1 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Overvoltage category | III |
---|---|
Pack Size | 50 |
Plug gauge acc. EN 60 947-1 | A5 |
Rated current cUL | 33 A |
Rated Current IEC | 41 A |
Rated Current To UL | 33 A |
Rated impulse voltage | 8 kV |
Rated wire cross section from (AWG) | 22 |
Rated wire cross section to (AWG) | 8 |
Rated voltage cUL | 300 V |
Rated Voltage IEC | 800 V |
Rated Voltage To UL | 300 V |
Screw size | M 3,5 |
Screw type | Slotted |
Stripping Length | 10 mm |
Tariff code | 85369010 |
Torque max | 2,4 Nm |
Torque Min | 1,2 Nm |
UL test standard | UL 1059 |
Weight | 26,084 g |
Width | 8,1 mm |
Test-disconnect terminals are mainly used for power network, electricity generation and supply applications.
They are perfect for the wide variety of switching demands in the current-transformer secondary circuits that are common in these types of applications.
Current transformers must always have a closed secondary circuit, for use when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
All versions provide touch-safe protection in compliance with DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
In all versions, the STBI 19/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
Cross-switches QVSI
The VH 19 connecting sleeves and the BS 25 screws or STB 19/4 L socket plugs are required for fastening the QVSI cross-switches above the terminal block. The cross-switches are available from 2 to 10 poles.
Cross-switches QSBI
The QSBI internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
Mounting screw BS 25
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVSI cross-switches.
Switch lock PTK-SP
The PTK-SP switch lock is mounted over the slider on the SPTK terminals. It keeps the partition screws from being accidentally touched by a screwdriver.
Insulated socket plugs STBI 19/4 L
The STBI 19/4 L socket plugs can be screwed into the inside cross-connection channels. They are used together with the VH 19 connecting sleeves to establish contact with the QVSI cross-switches. They are also used to hold the PS 4 test plugs or conventional (4 mm) insulated test plugs.
Short-circuit plug KS-SQI
The KS-SQI short-circuit plugs are used to make pluggable cross-connections between the SPTK terminals in the outer cross-connection channels. The plugs can also be put in the built-in park position of the SPTK terminals when not in use. The short-circuit plugs are available from 2 to 5 poles.
Cross-connector SQI 6
The SQI cross-connector is used to make a pluggable cross-connection between the SPTK terminals in the outer cross-connection channels. The cross-connectors can also be put in the built-in park position of the SPTK terminals when not in use. The cross-connectors are available from 2 to 30 poles.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
The need for flexible, modular systems shapes machine and system engineering. Decentralization of the system components has proven to be an important factor for success.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
The PIANO PIC series is designed for applications that require reliable DIN rail power supplies, which are focused to deliver the most widely required customer functionalities. Our PIC units offer this simplicity without making compromises on PULS’ renowned qualities; efficiency, service lifetime, reliability and size.
The new WADI product family by Jacob features a completely redesigned gland rubber, which allows extensive sealing and tightening area.
With the CP series, PULS offers a unique feature: Power supplies with an integrated decoupling function based on efficient MOSFET technology. This means there is no need for additional redundancy modules in 1+1 and n+1 redundant systems.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Additional information | Country of origin | Height TS 35/7.5 | Rated impulse voltage | Rated voltage cUL | Rated Voltage IEC | Rated Voltage To UL | Weight | ||
---|---|---|---|---|---|---|---|---|---|---|
SPTK 6/DU, Test Disconnect feed through terminal
Art:
17520.2
Copied
|
|
CZ
|
47 mm
|
8 kV
|
300 V
|
800 V
|
300 V
|
26,084 g
|
| |
SPTK 6/LT, Test Disconnect terminal, slide disconnect
Art:
17521.2
Copied
|
|
CZ
|
47 mm
|
4 kV
|
300 V
|
400 V
|
300 V
|
27,28 g
|
| |
SPTK 6/QT, Test Disconnect feed through terminal with slide disconnect
Art:
17522.2
Copied
|
|
CZ
|
47 mm
|
4 kV
|
150 V
|
400 V
|
150 V
|
28,19 g
|
| |
SPTK 6/LT/HB, Test Disconnect terminal, slide disconnect finger operated
Art:
17523.2
Copied
|
|
CZ
|
63 mm
|
4 kV
|
300 V
|
400 V
|
300 V
|
28,43 g
|
| |
SPTK 6/LT/STBI/YE, Test Disconnect terminal, slide disconnect with STBI, Yellow
Art:
17524.2
Copied
|
with sockets
|
DE
|
63 mm
|
4 kV
|
300 V
|
400 V
|
300 V
|
29,65 g
|
| |
SPTK 6/LT/STBI/BU, Test Disconnect terminal, slide disconnect with STBI, Blue
Art:
17525.2
Copied
|
with sockets
|
DE
|
63 mm
|
4 kV
|
300 V
|
400 V
|
300 V
|
29,65 g
|
|
Select a variant in the list