SCHAFFNER
The FN 9222 E IEC inlet filter combines an IEC inlet and mains filter with excellent filter attenuation in a small form factor and integrated earth line choke. Choosing the FN 9222 E product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. A wide selection on amperage ratings, output connections, mounting possibilities and filters for medical applications are designed to offer you the desired solution.
Typical applications include:
Approvals | CSA 22.2 N°8 1986, EN60939, IEC60939, UL 1283 |
---|---|
Capacitance Cx | 0,1 µF |
Capacitance Cy | 2,2 nF |
Connection Thread | Flat plug |
Flammability class | UL94-V2 |
Frequenze | DC-400 Hz |
High Potential Test Voltage "Hipot" | P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A). |
Inductance | 12 mH |
IP Class | IP40 |
Leakage Current Per Phase Max | 0,373 mA |
---|---|
MTBF (Mil-HB-217F) | 2256000 h @ 40° C, 230 V AC |
Operating Voltage Max | 250 V AC |
Rated current at 50 °C | 1 A |
Resistance | 1000 kΩ |
Temperature range from | -25 °C |
Temperature range to | 85 °C |
Weight | 0,04 kg |
The FN 9222 E IEC inlet filter combines an IEC inlet and mains filter with excellent filter attenuation in a small form factor and integrated earth line choke. Choosing the FN 9222 E product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. A wide selection on amperage ratings, output connections, mounting possibilities and filters for medical applications are designed to offer you the desired solution.
Typical applications include:
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
The need for flexible, modular systems shapes machine and system engineering. Decentralization of the system components has proven to be an important factor for success.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
The PIANO PIC series is designed for applications that require reliable DIN rail power supplies, which are focused to deliver the most widely required customer functionalities. Our PIC units offer this simplicity without making compromises on PULS’ renowned qualities; efficiency, service lifetime, reliability and size.
The new WADI product family by Jacob features a completely redesigned gland rubber, which allows extensive sealing and tightening area.
With the CP series, PULS offers a unique feature: Power supplies with an integrated decoupling function based on efficient MOSFET technology. This means there is no need for additional redundancy modules in 1+1 and n+1 redundant systems.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | High Potential Test Voltage "Hipot" | Inductance | IP Class | Rated current at 50 °C | Temperature range to | ||
---|---|---|---|---|---|---|---|
1 A IEC connection filter, flat terminal
Art:
FN9222R-1-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A).
|
12 mH
|
IP40
|
1 A
|
85 °C
|
| |
3 A IEC connection filter, flat terminal
Art:
FN9222R-3-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A).
|
2,5 mH
|
IP40
|
3 A
|
85 °C
|
| |
6 A IEC connection filter, flat terminal
Art:
FN9222R-6-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A).
|
0,78 mH
|
IP40
|
6 A
|
85 °C
|
| |
FILTER. 10A. FLAT PIN 6,3X0,8
Art:
FN9222R-10-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (30 A & 60 A). P->N 760 V DC, 2 s (1-20 A).
|
0,225 mH
|
|
10 A
|
100 °C
|
| |
12 A IEC connection filter, flat terminal
Art:
FN9222R-12-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A).
|
0,11 mH
|
IP40
|
12 A
|
85 °C
|
| |
15 A IEC connection filter, flat terminal
Art:
FN9222R-15-06
Copied
|
P->PE 2000 V AC, 2 s. P->N 1100 V DC, 2 s (16 A & 20 A). P->N 1000 V AC, 2 s (1-10 A).
|
0,075 mH
|
IP40
|
15 A
|
85 °C
|
|
Select a variant in the list