PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.481 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 92.8% with a peak value of 93.9%. In addition, power losses very low at idle, only 2.4 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example dc motors. If the output voltage drops below 25 V DC will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
For approved cooling, we recommend free space of 40 mm above. 20 mm under and 5 mm on the sides. (15 mm if there is another power supply)
|
Input voltage DC | 110-300 V |
---|---|
Input voltage dc min | 88 V DC |
Input voltage dc max | 360 V DC |
Inrush current | Typ. 6/4 A @ 110/300 V DC |
Max entrance tripple | 50 V pp |
Type Power Supply | AC-DC |
Start-Up Delay | 1100 ms |
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 56 V DC |
Output Current | 10 A |
Effect | 480 W |
Power Reduction Of 60 To 70 ° C | 12 W/°C |
Ripple. max | 50 mV pp |
Temperature Range Without Derating From | -25 °C |
Temperature Range Without Derating To | 60 °C |
Efficiency | 94.6 % |
---|---|
MTBF (IEC 61709) | 537000 h @ 10 A, 40 °C |
Width | 65 mm |
Height | 124 mm |
Depth | 117 mm |
Weight | 0.94 kg |
Clamp type | Screw |
Series | Dimension C |
Approvals | ATEX, CB, CE, CSA US, cRUus, cULus, IECEx |
DC relay output | Yes |
Material Protection | Aluminium |
Keep time | Typ. 26/26 ms @ 110/300 V DC |
IP Class | IP20 |
Active Transient | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.481 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 92.8% with a peak value of 93.9%. In addition, power losses very low at idle, only 2.4 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example dc motors. If the output voltage drops below 25 V DC will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
For approved cooling, we recommend free space of 40 mm above. 20 mm under and 5 mm on the sides. (15 mm if there is another power supply)
|
The need for flexible, modular systems shapes machine and system engineering. Decentralization of the system components has proven to be an important factor for success.
The PIANO PIC series is designed for applications that require reliable DIN rail power supplies, which are focused to deliver the most widely required customer functionalities. Our PIC units offer this simplicity without making compromises on PULS’ renowned qualities; efficiency, service lifetime, reliability and size.
With the CP series, PULS offers a unique feature: Power supplies with an integrated decoupling function based on efficient MOSFET technology. This means there is no need for additional redundancy modules in 1+1 and n+1 redundant systems.
ComatReleco has launched a new series of push-in sockets specifically designed for time and space savings.
Crouzet has honoured the strong Syrelec time relay traditions established in the 1980s, first by Cronos and Cronos 2 series. Now, Crouzet presents the compact and extremely versatile Syr-Line series.
The new WADI product family by Jacob features a completely redesigned gland rubber, which allows extensive sealing and tightening area.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Output voltage | Input voltage AC | Input voltage DC | Clamp type | Effect | Output Current | ||
---|---|---|---|---|---|---|---|---|
![]()
POWER SUPPLY 48VDC 480W 10A
Art:
CPS20.481
Copied
|
48 V DC
|
100-240 V
|
|
Screw
|
480 W
|
10 A
|
| |
![]()
Power supply 48VDC/10A. 110-300 VDC
Art:
CPS20.481-D1
Copied
|
48 V DC
|
|
110-300 V
|
Screw
|
480 W
|
10 A
|
|
Select a variant in the list